Dansensor
By combining a headspace gas analyzer, leak detector and valve tester in one unit, the Dansensor® MultiCheck® 2 helps you achieve fast, consistent, and reliable quality control of your MAP packaging process.
Inquiry| Specification | Details |
|---|---|
| Product Model | Dansensor® MultiCheck® 2 |
| Test Types | Headspace gas analysis; leak detection (burst and leak options); optional valve leak and valve release tests |
| Typical Test Time | 60–90 seconds (combined headspace and leak test on 500 g bag); dependent on test settings, package size, etc. |
| Heating Time (Max) | 10 min |
| Applications | Most MAP applications, including coffee bags and packaged pillow packs |
| Maximum Package Size | 5 liters |
| Headspace Analysis Sample Volume (Typical) | 25.7 ml |
| Headspace Analysis Measuring Range | 0–100% O₂ |
| Leak Detection Measuring Range | 10–1000 mbar (0.15–14.5 psi) / VTU mode: 0–350 mbar (0–5 psi) / Low range: 10–350 mbar / High range: 350–1000 mbar |
| Headspace Analysis Accuracy | ±0.25% O₂ + 2% of reading |
| Leak Detection Accuracy | Low range: ±0.5 mbar (0.007 psi) or ±0.5% of reading / High range: ±5 mbar (0.07 psi) or ±0.5% of reading |
| Number of Test Definitions | 999 |
| Data Collection Capacity | Test data from more than 100,000 tests |
| Data Export | Stored data to CSV file (USB) or real-time CSV-string transfer per test (RJ-45) |
| Dimensions (W × D × H) and Weight | Instrument: 304 × 236.5 × 185 mm (12 × 9.3 × 7.3 in), 4.4 kg (9.7 lbs) / Stand + Test Head: 250 × 330 × 410 mm (9.8 × 13.0 × 16.1 in), 4.0 kg (8.8 lbs) |
| Calibration and Service | 12 months |
| Ambient Temperature | Operational: +2°C to +35°C / Storage: -20°C to +60°C |
| Relative Humidity | Operational: 10 to 90% RH (non-condensing) / Storage: <95% RH (non-condensing) |
| Ambient Pressure | Operational: 750–1100 mbar |
| Power Supply and Consumption | External PSU, 100–240 VAC, 47–63 Hz / Max 40 W |
| Air Supply Pressure and Connection | 2–5 bar / Ø6/4 mm tube / DIN ISO 8573-1:2010 [4:4:3] |
| Air Consumption | Max 5 L/min (depending on test settings) |
| Connections | LAN: RJ-45 Ethernet 10/100 Mbit/s, DHCP client or fixed IP / USB: 1 x Host USB 2.0 Type A; 1 x Device USB 2.0 Type B (max current 500 mA) |
| Consumables and Accessories | Septa, VTU (Valve Test Unit) |
| Warranty | 12 months |
| Compliance | CE, China RoHS II |
| Standards | ASTM F2095, ISO 11607 |

Dansensor
High-accuracy tabletop headspace MAP gas analyzer.

Dansensor
Portable headspace MAP gas analyzer for packaging lines.

Dansensor
Multi-function tester for seal strength, burst, creep, and leak tests.

Dansensor
Vacuum leak detector for blister packs, vials, and rigid packages.

Dansensor
In-line leak detector to reduce waste and product returns.